Optical parameters
Detection area 0.5... 6 m
Aperture angle
-± 5 ° when the distance between the transmitting ends is 3 meters
-± 20 ° when the receiving end is spaced 3 meters apart
Light resistance intensity of 100000 Lux
Mechanical parameters
Protection level IP67
Temperature range -20 ° C...+60 ° C
Electronic parameters
Supply voltage Usp 10 30 VDC
Current consumption
-Transmitting end<12 mA at 20 VDC
-Receiving end<10 mA at 20 VDC
Output PNP/NPN
Maximum output current of 200 mA (short circuit protection)
Maximum output saturation voltage 2.5 V
Rise time - Receiver 20 ms
Descent time -20 ms at the receiving end
Cable and electrical connections
Cable length (cable or plug) 5/10/20 m
Diameter Ø 3.5 mm
Cable color
-Black transmitting end
-Receiving end gray
Transmitting end - Cable 2 × 0.14 mm ², AWG26
• Brown Usp
• Blue GND (0 V)
Receiver - Cable 3 × 0.14 mm2, AWG26
• Brown Usp
• Blue GND (0 V)
• Black output