LCMA121 amplifier
Signal output relay resistive load: 1A/60V ac
Detection mode for moving objects
Power supply voltage 24V DC ± 30%
Withstand impulse voltage 2kV
Power consumption<1.8W
Protection level IP20
Storage temperature -40 ℃~+80 ℃ (without condensation)
Working temperature -25 ℃~+65 ℃ (non condensing) EMC
Compliant with EMC 2014/30/EU standards
Terminal torque 0.4Nm
Shell material flame retardant ABS
LCMS025
Transmission frequency 24.125 GHz
Detection distance 2m (adjustable)
Transmission power<20 dBm EIRP
Detection mode for moving objects
Protection level IP67
Cable length 2.5m
Shell material flame retardant ABS
Compliant with EMC 2014/30/EU standards
Storage temperature -40 ℃~+80 ℃ (without condensation)
Working temperature -25 ℃~+65 ℃ (without condensation)
Installation instructions
1. Tilt angle: Horizontal -30 °~+30 °.
2. It is recommended that the vertical height above the ground be greater than 15CM, or tilt upwards by 15 °~20 °
3. The sensor is installed inside the inner skirt below the handrail.
When installing inside the metal skirt, a 30mm diameter circular hole is opened on the skirt, and then the circular hole is sealed with a plastic plate to allow the sensor to detect passengers through the plastic circular hole.
5. The sensor should cover the required detection area in front of the escalator. We recommend tilting the sensor inward by 10-30 degrees (depending on the width of the escalator) to avoid unnecessary area detection.
Quantity of one escalator: 2 LCMA121 and 4 LCMS025