home>>Escalator parts >> LCM101 amplifier+LCMS050 probe Australian Celex dual loop microwave radar sensor data sharing

LCM101 amplifier+LCMS050 probe Australian Celex dual loop microwave radar sensor data sharing

时间:2024-09-01 11:05:17 本站 点击:20

微信截图_20230523153502.png

LCM101 amplifier

Signal output relay resistive load: 1A/60V ac

Detection mode for moving objects

Power supply voltage 24V DC ± 30%

Withstand impulse voltage 2kV

Power consumption<2W

Protection level IP20

Storage temperature -40 ℃~+80 ℃ (without condensation)

Working temperature -25 ℃~+65 ℃ (non condensing) EMC

Compliant with EMC 2014/30/EU standards

Terminal torque 0.4Nm

Shell material flame retardant ABS

    lcm101.png

LCMS050

Transmission frequency 24.125 GHz

Detection distance 2m (adjustable)

Transmission power<20 dBm EIRP

Detection mode for moving objects

Minimum detection speed 5cm/s (along the longitudinal axis of the sensor)

Protection level IP67

Cable length 5m (LCMS050 0.4/T3 is a 0.4m cable with 3Pin and M8 * 1 plug)

Shell material flame retardant ABS

Compliant with EMC 2014/30/EU standards

Storage temperature -40 ℃~+80 ℃ (without condensation)

Working temperature -25 ℃~+65 ℃ (without condensation)

微信截图_20230523155910.png

Installation instructions

1. Tilt angle: Horizontal -30 °~+30 °.

2. It is recommended that the vertical height above the ground be greater than 15CM, or tilt upwards by 15 °~20 °

3. The sensor is installed inside the inner skirt below the handrail.

When installing inside the metal skirt, a 30mm diameter circular hole is opened on the skirt, and then the circular hole is sealed with a plastic plate to allow the sensor to detect passengers through the plastic circular hole.

5. The sensor should cover the required detection area in front of the escalator. We recommend tilting the sensor inward by 10-30 degrees (depending on the width of the escalator) to avoid unnecessary area detection.


Quantity of one escalator: 2 LCM101 and 4 LCMS050


Latest articles