home>>Escalator parts >> MA-DTD24-K3 amplifier+MS-24G-5-K3 probe Australian Celex dual loop microwave radar sensor data sharing

MA-DTD24-K3 amplifier+MS-24G-5-K3 probe Australian Celex dual loop microwave radar sensor data sharing

时间:2024-09-01 10:25:15 本站 点击:22

微信截图_20230523153844.png

MA-DTD24-K3 amplifier

Signal output relay resistive load: 7A/250V ac

Output delay of 1-60 seconds (adjustable)

Fault output resistive load: 125 V ac/1A

Detection mode for moving objects

Power supply voltage 24 V DC ± 30%

Withstand impulse voltage 2kV

Power consumption<2W

Protection level IP20

Storage temperature -40 ℃~+80 ℃ (without condensation)

Working temperature -25 ℃~+65 ℃ (without condensation)

Compliant with EMC 2004/108EC standard

Terminal torque 0.4Nm

Shell material PPO

图片2.png

MS-24G-5-K3

Transmission frequency 24.125 GHz

Detection distance 3m (adjustable)

Transmission power<20 dBm EIRP

Detection mode for moving objects

Protection level IP67

Cable length 5m

Shell material flame retardant ABS

Compliant with EMC 2014/30/EU standards

Storage temperature -40 ℃~+85 ℃ (without condensation)

Working temperature -25 ℃~+65 ℃ (without condensation)

图片3.png

Installation instructions

1. Tilt angle: Horizontal -30 °~+30 °.

2. It is recommended that the vertical height above the ground be greater than 15CM, or tilt upwards by 15 °~20 °

3. The sensor is installed inside the inner skirt below the handrail.

When installing inside the metal skirt, a 30mm diameter circular hole is opened on the skirt, and then the circular hole is sealed with a plastic plate to allow the sensor to detect passengers through the plastic circular hole.

When installing inside the plastic skirt, there is no need to open holes on the skirt

6. Two sensors jointly cover the required detection area in front of the escalator. We suggest tilting the sensor inward by 10-30 degrees (depending on the width of the escalator) to avoid unnecessary area detection by the sensor.